Enerdrive B-TEC Lithium Battery 12V 100AH
Enerdrive 12v B-TEC 100AH LIFEPO4 BATTERY GEN2
The Enerdrive B-TEC battery provides 60% more usable power than its equivalent lead acid cousin and being nearly 50% lighter and 30% smaller makes for a superior alternative.
The G2 now incorporates a “Built-In Reset Button” making re-starting a flat battery a breeze. No longer do you need to apply a voltage to the battery terminals to wake up the battery. Press the button and within seconds, the battery will come back to life ready to accept a charge source to rejuvenate the battery.
The Enerdrive B-TEC battery is perfect for camper trailers, 4WD’s (AUX battery), caravans, small water craft, low power communication sites or any other application that requires the use of a single deep cycle battery that meets the amp hour capacity.
With over 7 years of researching, designing and testing lithium batteries and the associated charging systems, Enerdrive are at the forefront of lithium battery systems in Australia. Enerdrive are the only Australian company that can supply a fully integrated self-branded energy system to suit your setup.
Features:
Battery Management System - The BMS helps to ensure safe and accurate operation of the battery.
Lithium v AGM Capacities: 100Ah Lithium = 160Ah AGM
Specifications:
Nominal Voltage: 12.8V
Nominal Capacity: 100Ah
Cycle Life (DOD – 80% under controlled conditions): ≥ 2000 Cycles
Standard Charge Specification (Lithium profile charger required)
Battery Charge Temperature: 0 ̴ 45°C
Normal Charge Voltage CV/CC*: 14.20 ̴ 14.60V
Standby (Float) Voltage: 13.50 ̴ 13.80V
Maximum Charge Current: 60A @ 25°C for 30mins
For Maximum Life, Charge in the lower amperage range": 20~60A
Standard Discharge Specification:
Battery Discharge Temperature: -20 ̴ 60°C
Battery Output Voltage Range: 11.00 ̴ 14.60V
Maximum Discharge/Pulse Current: 100A @ 25˚C ±5˚C for 30 mins
Pulse Discharge Current: 450A for 1.0s
Discharge Cut-off Voltage: ≤11.20V
Over-charge Protection Per Cell: 3.90V ± 0.03V
Over-charge Release Per Cell: 3.60V ± 0.05V
Over-charge Release Method: Discharge below release voltage
Over-discharge Protection Per Cell: 2.80V ± 0.05V
Over-discharge Release Per Cell: 3.20V ± 0.05V
Over-discharge Release Method: Apply Charge/Voltage ≥12.8V
Discharge Over Current: 110A for 30s – 450A for 1s
Protection Reset Time:Approx 10s Auto Release
Over Current Release Method: Disconnect Load
Battery Discharge Over Temperature: Protection to 65°C ± 5°C
Release at 50°C ± 5°C
Battery Charge Over Temperature Protection to 55°C ± 5°C
Release at 45°C ± 5°C
Short Circuit Protection: Auto release after 5s
Dimensions (mm): 318L x 165W x 232H
Weight: Approx 12.6kg
Case Construction: Hi Impact ABS Plastic
Temperature & Humidity Range: ≤ 30 days -20°C ̴ 60°C, 5 ̴ 75% RH
≥ 90 days -10°C ̴ 45°C, 5 ̴ 75% RH
Voltage | 12V |
---|---|
Amp/hrs | 100Ah |
Dimensions (mm) | 318L X 165W X 232H - Designed to be mounted in the upright position. |
Weight | 12.6kg |
FOR ORDERS UNDER $399 VALUE:
Urban Delivery $9.90
Rural Delivery $14.90
FOR ORDERS OVER $399 VALUE: Free Delivery *
* We reserve the right to revise the free delivery offer on some bulky items (for example, a large fridge travelling to Te Anau). In this case, we will endeavor to offer a subsidized freight cost. If the delivery address is outside the North and South Islands (eg. Waiheke, Great Barrier, Stewart Islands), please contact us for a freight quote.
WE ONLY SEND ORDERS WITHIN NEW ZEALAND. If the delivery address is outside the North or South Islands (eg. Waiheke, Great Barrier, Stewart Islands), please contact us for a freight quote. Our automated online freight pricing only applies to North & South Island locations.
DELIVERY TIMES Due to the current outbreak, we are experience some disruptions to our normal service. Order dispatch and delivery times are being impacted by workforce sickness and isolation requirements for staff throughout our team and our supply chain. Although we use many courier options, the below NZ Couriers Network Status will give a good indication which regions are experiencing significant freight delays
https://www.nzcouriers.co.nz/network-status/
As a general rule, please allow an additional 3 working days for the below estimates (which may be extended by factors outside our control).
North Island (2-4 working days)
North Island Rural (3-5 working days)
South Island (2-5 working days)
South Island Rural (3-6 working days)